Find usg product specific cad and revit files.
2 hr rated roof assembly.
Our cad and revit library of design drawings of wall intersections joints and other construction details.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring channel spaced 12 o c.
These assemblies need to meet fire and smoke safety and environmental sustainability requirements.
With 1 2 wood structural panels with.
276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr.
Ibc table 721 3 item 21 1 1 describes a single prescriptive 1 hour rated floor or roof assembly that includes wood trusses.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
Fire rated construction acoustical performance partition applications fire detail physical data description test no.
All new fire rated roof ceiling assembly files.
12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr.
Fire rated wall floor and ceiling assemblies provide the necessary fire and smoke barriers to create compartmentalization during a fire safeguarding against the spread of fire and smoke within a building or to and from a building.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
These listings are short summaries to serve as a.
Screw fastened perpendicular to lower chord of wood trusses of 2 x 4 38 mm x 89 mm.
3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete.
Wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c.
Lp flameblock fire rated osb sheathing is a component of the following code compliant fire rated assemblies.
Shaft wall limiting heights spans.
Concrete with cellular steel 3 hr.
6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
2 hour exterior wall assembly ul design no.
V337 2 hour interior wall assembly ul design no.
With 1 25 mm type s drywall screws 12 305 mm o c.
Urb concealed grid system and tile.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.